Pitch Epoxy Coating
(Standard/Flexible/Waterbased)
Technical Data Sheet
1.
DESCRIPTION
Antel
Pitch Epoxy Coating is a pitch extended epoxy coating which when
fully cured forms a permanent water barrier.
A two part material available in STANDARD, FLEXIBLE AND
SOLVENT FREE (WATERBASED) grades.
2.
USES
Pitch
Epoxy Coating forms a tough flexible membrane with superb adhesion
to concrete and other building material to provide:-
1.
A water and vapour proof membrane
2.
A chemical resistant membrane.
3.
An abrasion resistant coating.
3.
PACKAGING
2.5
litres or 5 litres (when the two parts are mixed together).
4.
COVERAGE
8
- 15 square metres per 5 litres depending on the thickness of
application and the substrate.
5.
STORAGE
Store
in cool dry conditions in original containers.
Protect from freezing.
Keep out of reach of children.
The
STANDARD and FLEXIBLE grades are flammable and should be stored
away from naked lights and flames.
Shelf
life is in excess of 12 months in unopened containers.
6.
COLOUR
Black
7.
HEALTH & SAFETY
These
products contain epoxy resin and hardeners which are known to
cause skin irritation to some people.
Wear protective clothing and wash well on completion of
each session of work. The
STANDARD and FLEXIBLE grades contain solvents and must only be
used in well ventilated areas.
Should
the fluid come into contact with the skin it must be washed off
promptly. If in
contact with the eyes flush copiously with cold water and seek
medical attention.
Please
refer to the safety data sheet for complete information.
8.
INSTRUCTIONS FOR USE.
8.1
PREPARATION
Surfaces
must be free of all loose and flaking paint, dust, dirt, laitance
or grease. It is most
important that surfaces are properly prepared.
Iron or steel must be wire brushed to produce a bright
finish. Surfaces may
be damp but not wet.
8.2
MIXING
Empty
the entire contents of the smaller container into the larger
container taking care that ALL the product is added.
Mix thoroughly with a paint mixer or a hand held electric
drill or with a paint paddle.
8.3
APPLICATION
The
mixed material should be applied as soon after mixing as possible,
using a brush or a roller. The
coverage should be as thick as the level of protection required.
The thicker the coat the better the level of protection.
Further coats may be applied as soon as the previous coat
is tack free. If
rendering or screeding after the final coat a quantity of 3 mm
granite chippings should be pressed into the surface before the
coating has cured. Apply
the chippings at a rate of 4 - 6 kilos per square metre.
|